Academic Article

Publisert

  • 2023

Although the use of asbestos fibres in building materials has been prohibited in Norway since 1985, asbestos-containing materials (ACMs) are still found in many buildings. Lack of knowledge and awareness of these materials may lead to exposure during refurbishing. The aim of this study was to investigate the airborne fibre concentration and classify fibres found during the abatement of various ACMs. The release of fibres during short-term work tasks, such as drilling and sawing, was also investigated. Parallel air samples were collected during asbestos abetment of different building materials and analysed with scanning electron microscope (SEM) and phase-contrast microscope (PCM), respectively. Material samples were analysed with SEM. A real-time fibre monitor was used to measure asbestos during short-term work. The highest fibre concentrations were measured for samples collected during the removal of asbestos insulating boards (1.5–4.5 fibres/cm3 [f/cm3]), and the numbers were relatively similar for SEM and PCM. A large difference in asbestos concentrations was found between SEM and PCM when analysing floor materials, which were probably caused by a high number of gypsum fibres that the PCM operator counted. Thin fibres (<0.2 µm in width) were included in the SEM count and constituted up to 50% of the total...

Ervik, Torunn Kringlen; Hammer, Stine Eriksen; Skaugset, Nils Petter; Graff, Pål
Annals of Work Exposures and Health 67(8): 952–964
Read publication